ELECTRO-MAGNETIC /
EDDY CURRENT COATING THICKNESS METERS
Exclusive probes for SWT series 
Fe-2.5Fe-0.6PenFe-10
NFe-2.0NFe-8
Separate-interchangeable probes available with a main unit.
Selections of probe for ferrous (electro-magnetic) or non-ferrous ( eddy current) substrate depending on a measuring object.
Capability of selections probe like high-stable probe to measure minute piece objects or alike depending on applications and a measurement range.
Specifications of SWT (Fe probes)
ModelsFe-2.5※1/2.5LFe-2.5LwAFe-0.6Pen
MethodsMagnetic inducing type
Ranges0~2.50mm0~600μm
Display resolutions1μm:0~999μm
switching to
0.1μm:0~400μm
0.5μm:400~500μm
0.01mm:1.00~2.50mm
1μm:0~600μm
switching to
0.1μm:0~400μm
0.5μm:401~500μm
Accuracies
(perpendicularly
testing on
flat face)
0~100μm:±1μm
or ±2% the reading value
101μm~2.50mm:±2%
0~100μm:±1μm or ±2% the reading value
101μm~600μm:
±2% the reading value
ProbesOne point contact constant pressure type,
V cut
2.5:φ13×48mm
2.5L:18x23x67mm
One point contact constant pressure type,
Measuring part:About 20x57mm
Total Length: about 550~1,550mm (flexible)
One point contact constant pressure type, V cut
φ5.6x94mm
V type probe adaptors※2
/Non
Non
AccessoriesStandard thickness,
Zero plate for testing (Fe)
Standard thickness,
Zero plate for testing (Fe)
Carrying case
Standard thickness,
Zero plate for testing (Fe)
Measuring objectsCoating, lining, thermal spray films, plating (except electrolyte nickel plating) etc. on magnetic metal substrate like iron, steel.Coating, lining, plating on high/hard-to-reach/remote place on magnetic metal substrate like iron, steel.Coating, lining, plating on a narrow/small place and part substrate like iron, steel.
※1.Probes are heat-resistant (about 200℃). (Fe-2..5)
※2.V type probe adaptors (3 kinds: lessΦ5, Φ5~10, Φ10~20) can be used with Fe-2.5.
ModelsFe-10Fe-20
MethodsMagnetic inducing type
Ranges0~10mm0~20mm
Display resolutions1μm:0~999μm
0.01mm:1~10mm
1μm:0~999μm
0.01mm:1~5mm
0.1mm:5~20mm
Accuracies
(perpendicularly
testing on flat
face)
0~3mm:±(5μm + 3% the read value)
Over or 3.01mm:±3% the read value
ProbesOne point contact constant pressure type, V cut
φ18x47mm
One point contact constant pressure type, V cut
φ35x59mm
AccessoriesStandard thickness,
Zero plate for testing (Fe)
Measuring  objectsRelatively thicker objectsThick objects
Probe must be ordered separately.
Specifications of SWT (NFe probes)
ModelsNFe-2.0※1/2.0LNFe-0.6NFe-8
MethodsEddy current type
Ranges0~2.00mm0~600μm0~8mm
Display
resolutions
1μm:0~999μm
switching to
0.1μm:0~400μm
0.5μm:400~500μm
0.01mm:1.00~2.00mm
1μm:0~600μm
switching to
0.1μm:0~400μm
0.5μm:400~500μm
1μm:0~999μm
0.01mm:1~8mm
Accuracies
(perpendicularly
on flat face)
0~100μm:±1μm
or ±2% the read value
101μm~2.00mm:±2%
0~100μm:±1μm
or ±2% the read value
101μm~600μm:±2%
0~3mm:±(5μm + ±3% the read value)
Over or 3.01mm:±3% the read value
ProbesOne point contact constant pressure type, V cut
2.0:φ13×47mm
2.0L:18x23x67mm
One point contact constant pressure type,
φ11×48mm
One point contact constant pressure type, V cut
φ35×61mm
V type probe adaptor※2/NonNon
AccessoriesStandard thickness, Zero plate for testing (NFe)
Measuring
objects
Insulated films on non-Magnetic metal substrates like aluminum, cupper
Relatively general use objectslike aluminum, cupper for high stability for narrow bar , tube, minute piecesRelatively thick objects
Probe must be ordered separately.
※1.Probes are heat-resistant (about 200℃). (NFe-2.0)
※2.V type probe adaptors (3 kinds:lessΦ5, Φ5~10, Φ10~20) can be used with NFe-2.0.